This article describes how to troubleshoot problems related to Solaris Volume Manager and provides both general troubleshooting guidelines and specific procedures for resolving some particular known problems.
This article describes some Solaris Volume Manager problems and their appropriate solution. It is not intended to be all-inclusive but rather to present common scenarios and recovery procedures.
Troubleshooting Solaris Volume Manager (Task Map)
The following task map identifies some procedures needed to troubleshoot Solaris Volume Manager.
Overview of Troubleshooting the System
Prerequisites for Troubleshooting the System
To troubleshoot storage management problems related to Solaris Volume Manager, you need to do the following:
Have root privilege
Have a current backup of all data
General Guidelines for Troubleshooting Solaris Volume Manager
You should have the following information on hand when you troubleshoot Solaris Volume Manager problems:
Output from the metadb command.
Output from the metastat command.
Output from the metastat -p command.
Backup copy of the /etc/vfstab file.
Backup copy of the /etc/lvm/mddb.cf file.
Disk partition information, from the prtvtoc command (SPARC® systems) or the fdisk command (x86–based systems)
Solaris version
Solaris patches installed
Solaris Volume Manager patches installed
Tip –
Any time you update your Solaris Volume Manager configuration, or make other storage or operating environment-related changes to your system, generate fresh copies of this configuration information. You could also generate this information automatically with a cron job.
General Troubleshooting Approach
Although there is no one procedure that will enable you to evaluate all problems with Solaris Volume Manager, the following process provides one general approach that might help.
Gather information about current configuration.
Look at the current status indicators, including the output from the metastat and metadb commands. There should be information here that indicates which component is faulty.
Check the hardware for obvious points of failure. (Is everything connected properly? Was there a recent electrical outage? Have you recently added or changed equipment?)
Replacing Disks
This section describes how to replace disks in a Solaris Volume Manager environment.
Caution –
If you have soft partitions on a failed disk or on volumes built on a failed disk, you must put the new disk in the same physical location, with the same c*t*d* number as the disk it replaces.
How to Replace a Failed Disk
Identify the failed disk to be replaced by examining the /var/adm/messages file and the metastat command output.
Locate any state database replicas that might have been placed on the failed disk.
Use the metadb command to find the replicas.
The metadb command might report errors for the state database replicas located on the failed disk. In this example, c0t1d0 is the problem device.
# metadb flags first blk block count a m u 16 1034 /dev/dsk/c0t0d0s4 a u 1050 1034 /dev/dsk/c0t0d0s4 a u 2084 1034 /dev/dsk/c0t0d0s4 W pc luo 16 1034 /dev/dsk/c0t1d0s4 W pc luo 1050 1034 /dev/dsk/c0t1d0s4 W pc luo 2084 1034 /dev/dsk/c0t1d0s4 |
The output shows three state database replicas on slice 4 of the local disks, c0t0d0 and c0t1d0. The W in the flags field of the c0t1d0s4 slice indicates that the device has write errors. Three replicas on the c0t0d0s4 slice are still good.
Record the slice name where the state database replicas reside and the number of state database replicas, then delete the state database replicas.
The number of state database replicas is obtained by counting the number of appearances of a slice in the metadb command output. In this example, the three state database replicas that exist on c0t1d0s4 are deleted.
Caution –
If, after deleting the bad state database replicas, you are left with three or fewer, add more state database replicas before continuing. This will help ensure that configuration information remains intact.
Locate and delete any hot spares on the failed disk. Use the metastat command to find hot spares. In this example, hot spare pool hsp000 included c0t1d0s6, which is then deleted from the pool.
# metahs -d hsp000 c0t1d0s6 hsp000: Hotspare is deleted |
Physically replace the failed disk.
Logically replace the failed disk using the devfsadm command, cfgadm command, luxadm command, or other commands as appropriate for your hardware and environment.
Update the Solaris Volume Manager state database with the device ID for the new disk using the metadevadm -u cntndn command.
In this example, the new disk is c0t1d0.
Repartition the new disk.
Use the format command or the fmthard command to partition the disk with the same slice information as the failed disk. If you have the prtvtoc output from the failed disk, you can format the replacement disk with fmthard -s /tmp/failed-disk-prtvtoc-output
If you deleted state database replicas, add the same number back to the appropriate slice.
In this example, /dev/dsk/c0t1d0s4 is used.
# metadb -a -c 3 c0t1d0s4 |
If any slices on the disk are components of RAID 5 volumes or are components of RAID 0 volumes that are in turn submirrors of RAID 1 volumes, run the metareplace -e command for each slice.
In this example, /dev/dsk/c0t1d0s4 and mirror d10 are used.
# metareplace -e d10 c0t1d0s4 |
If any soft partitions are built directly on slices on the replaced disk, run the metarecover -d -p command on each slice containing soft partitions to regenerate the extent headers on disk.
In this example, /dev/dsk/c0t1d0s4 needs to have the soft partition markings on disk regenerated, so is scanned and the markings are reapplied, based on the information in the state database replicas.
# metarecover c0t1d0s4 -d -p |
If any soft partitions on the disk are components of RAID 5 volumes or are components of RAID 0 volumes that are submirrors of RAID 1 volumes, run the metareplace -e command for each slice.
In this example, /dev/dsk/c0t1d0s4 and mirror d10 are used.
# metareplace -e d10 c0t1d0s4 |
If any RAID 0 volumes have soft partitions built on them, run the metarecover command for each of the RAID 0 volume.
In this example, RAID 0 volume d17 has soft partitions built on it.
Replace hot spares that were deleted, and add them to the appropriate hot spare pool or pools.
# metahs -a hsp000 c0t0d0s6 hsp000: Hot spare is added |
If soft partitions or non-redundant volumes were affected by the failure, restore data from backups. If only redundant volumes were affected, then validate your data.
Check the user/application data on all volumes. You might have to run an application-level consistency checker or use some other method to check the data.
Example—Replacing a Failed Disk
In the following example, a disk (/dev/dsk/c0t1d0) has failed and needs to be replaced.
panic[cpu0]/thread=70a41e00: md: state database problem ok boot -s Resetting ... Jun 7 08:57:25 su: 'su root' succeeded for root on /dev/console Sun Microsystems Inc. SunOS 5.9 s81_39 May 2002 # metadb flags first blk block count a m p lu 16 8192 /dev/dsk/c0t0d0s7 a p l 8208 8192 /dev/dsk/c0t0d0s7 a p l 16400 8192 /dev/dsk/c0t0d0s7 # |
SOME TEXT HERE.
Recovering from Disk Movement Problems
This section describes how to recover from unexpected problems after moving disks in the Solaris Volume Manager environment.
Disk Movement and Device ID Overview
Solaris Volume Manager uses device IDs, which are associated with a specific disk, to track all disks used in a Solaris Volume Manager configuration. When disks are moved to a different controller or when the SCSI target numbers change, Solaris Volume Manager usually correctly identifies the movement and updates all related Solaris Volume Manager records accordingly, and no system administrator intervention is required. In isolated cases, Solaris Volume Manager cannot completely update the records and reports an error on boot.
Resolving Unnamed Devices Error Message
If you add new hardware or move hardware (for example, move a string of disks from one controller to another controller), Solaris Volume Manager will check the device IDs associated with the disks that moved, and update the c*t*d* names in internal Solaris Volume Manager records accordingly. If the records cannot be updated, the boot processes spawned by /etc/rc2.d/S95svm.sync (linked to /etc/init.d/svm.sync) will report an error to the console at boot time:
Unable to resolve unnamed devices for volume management. Please refer to the Solaris Volume Manager documentation, Troubleshooting section, at http://docs.sun.com or from your local copy." |
No data loss has occured, and none will occur as a direct result of this problem. This error message indicates that the Solaris Volume Manager name records have been only partially updated, so output from the metastat command will likely show some of the c*t*d* names previously used, and some of the c*t*d* names reflecting the state after the move.
If you need to update your Solaris Volume Manager configuration while this condition exists, you must use the c*t*d* names reported by the metastat command when you issue any meta* commands.
If this error condition occurs, you can do one of the following to resolve the condition:
Restore all disks to their original locations. Next, do a reconfiguration reboot, or run (as a single command):
/usr/sbin/devfsadm && /usr/sbin/metadevadm -r |
After these commands complete, the error condition will be resolved and you can continue.
Contact your support representative for guidance
Note –
This error condition is quite unlikely to occur. If it does occur, it is most likely to affect Fiber Channel-attached storage.
Recovering From Boot Problems
Because Solaris Volume Manager enables you to mirror the root (/), swap, and /usr directories, special problems can arise when you boot the system, either through hardware failures or operator error. The tasks in this section provide solutions to such potential problems.
The following table describes these problems and points you to the appropriate solution.
Table 25–1 Common Solaris Volume Manager Boot Problems
Background Information for Boot Problems
If Solaris Volume Manager takes a volume offline due to errors, unmount all file systems on the disk where the failure occurred. Because each disk slice is independent, multiple file systems can be mounted on a single disk. If the software has encountered a failure, other slices on the same disk will likely experience failures soon. File systems mounted directly on disk slices do not have the protection of Solaris Volume Manager error handling, and leaving such file systems mounted can leave you vulnerable to crashing the system and losing data.
Minimize the amount of time you run with submirrors disabled or offline. During resynchronization and online backup intervals, the full protection of mirroring is gone.
How to Recover From Improper /etc/vfstab Entries
If you have made an incorrect entry in the /etc/vfstab file, for example, when mirroring root (/), the system will appear at first to be booting properly then fail. To remedy this situation, you need to edit the /etc/vfstab file while in single-user mode.
The high-level steps to recover from improper /etc/vfstab file entries are as follows:
Booting the system to single-user mode
Running the fsck command on the mirror volume
Remounting file system read-write
Optional: running the metaroot command for a root (/) mirror
Verifying that the /etc/vfstab file correctly references the volume for the file system entry
Rebooting
Example—Recovering the root (/) RAID 1 (Mirror) Volume
In the following example, root (/) is mirrored with a two-way mirror, d0. The root (/) entry in the /etc/vfstab file has somehow reverted back to the original slice of the file system, but the information in the /etc/system file still shows booting to be from the mirror d0. The most likely reason is that the metaroot command was not used to maintain the /etc/system and /etc/vfstab files, or an old copy of the/etc/vfstab file was copied back.
The incorrect /etc/vfstab file would look something like the following:
#device device mount FS fsck mount mount #to mount to fsck point type pass at boot options # /dev/dsk/c0t3d0s0 /dev/rdsk/c0t3d0s0 / ufs 1 no - /dev/dsk/c0t3d0s1 - - swap - no - /dev/dsk/c0t3d0s6 /dev/rdsk/c0t3d0s6 /usr ufs 2 no - # /proc - /proc proc - no - swap - /tmp tmpfs - yes - |
Because of the errors, you automatically go into single-user mode when the system is booted:
ok boot ... Configuring network interfaces: hme0. Hostname: lexicon mount: /dev/dsk/c0t3d0s0 is not this fstype. setmnt: Cannot open /etc/mnttab for writing INIT: Cannot create /var/adm/utmp or /var/adm/utmpx INIT: failed write of utmpx entry:" " INIT: failed write of utmpx entry:" " INIT: SINGLE USER MODE Type Ctrl-d to proceed with normal startup, (or give root password for system maintenance): <root-password> |
At this point, root (/) and /usr are mounted read-only. Follow these steps:
Run the fsck command on the root (/) mirror.
Note –
Be careful to use the correct volume for root.
# fsck /dev/md/rdsk/d0 ** /dev/md/rdsk/d0 ** Currently Mounted on / ** Phase 1 - Check Blocks and Sizes ** Phase 2 - Check Pathnames ** Phase 3 - Check Connectivity ** Phase 4 - Check Reference Counts ** Phase 5 - Check Cyl groups 2274 files, 11815 used, 10302 free (158 frags, 1268 blocks, 0.7% fragmentation) |
Remount root (/) read/write so you can edit the /etc/vfstab file.
# mount -o rw,remount /dev/md/dsk/d0 / mount: warning: cannot lock temp file </etc/.mnt.lock> |
Run the metaroot command.
This command edits the /etc/system and /etc/vfstab files to specify that the root (/) file system is now on volume d0.
Verify that the /etc/vfstab file contains the correct volume entries.
The root (/) entry in the /etc/vfstab file should appear as follows so that the entry for the file system correctly references the RAID 1 volume:
#device device mount FS fsck mount mount #to mount to fsck point type pass at boot options # /dev/md/dsk/d0 /dev/md/rdsk/d0 / ufs 1 no - /dev/dsk/c0t3d0s1 - - swap - no - /dev/dsk/c0t3d0s6 /dev/rdsk/c0t3d0s6 /usr ufs 2 no - # /proc - /proc proc - no - swap - /tmp tmpfs - yes - |
Reboot the system.
The system returns to normal operation.
How to Recover From a Boot Device Failure
If you have a root (/) mirror and your boot device fails, you'll need to set up an alternate boot device.
The high-level steps in this task are as follows:
Booting from the alternate root (/) submirror
Determining the errored state database replicas and volumes
Repairing the failed disk
Restoring state database and volumes to their original state
In the following example, the boot device contains two of the six state database replicas and the root (/), swap, and /usr submirrors fails.
Initially, when the boot device fails, you'll see a message similar to the following. This message might differ among various architectures.
Rebooting with command: Boot device: /iommu/sbus/dma@f,81000/esp@f,80000/sd@3,0 The selected SCSI device is not responding Can't open boot device ... |
When you see this message, note the device. Then, follow these steps:
Boot from another root (/) submirror.
Since only two of the six state database replicas in this example are in error, you can still boot. If this were not the case, you would need to delete the inaccessible state database replicas in single-user mode. This procedure is described in How to Recover From Insufficient State Database Replicas.
When you created the mirror for the root (/) file system, you should have recorded the alternate boot device as part of that procedure. In this example, disk2 is that alternate boot device.
ok boot disk2 SunOS Release 5.9 Version s81_51 64-bit Copyright 1983-2001 Sun Microsystems, Inc. All rights reserved. Hostname: demo ... demo console login: root Password: <root-password> Dec 16 12:22:09 lexicon login: ROOT LOGIN /dev/console Last login: Wed Dec 12 10:55:16 on console Sun Microsystems Inc. SunOS 5.9 s81_51 May 2002 ... |
Determine that two state database replicas have failed by using the metadb command.
# metadb flags first blk block count M p unknown unknown /dev/dsk/c0t3d0s3 M p unknown unknown /dev/dsk/c0t3d0s3 a m p luo 16 1034 /dev/dsk/c0t2d0s3 a p luo 1050 1034 /dev/dsk/c0t2d0s3 a p luo 16 1034 /dev/dsk/c0t1d0s3 a p luo 1050 1034 /dev/dsk/c0t1d0s3 |
The system can no longer detect state database replicas on slice /dev/dsk/c0t3d0s3, which is part of the failed disk.
Determine that half of the root (/), swap, and /usr mirrors have failed by using the metastat command.
# metastat d0: Mirror Submirror 0: d10 State: Needs maintenance Submirror 1: d20 State: Okay ... d10: Submirror of d0 State: Needs maintenance Invoke: "metareplace d0 /dev/dsk/c0t3d0s0 <new device>" Size: 47628 blocks Stripe 0: Device Start Block Dbase State Hot Spare /dev/dsk/c0t3d0s0 0 No Maintenance d20: Submirror of d0 State: Okay Size: 47628 blocks Stripe 0: Device Start Block Dbase State Hot Spare /dev/dsk/c0t2d0s0 0 No Okay d1: Mirror Submirror 0: d11 State: Needs maintenance Submirror 1: d21 State: Okay ... d11: Submirror of d1 State: Needs maintenance Invoke: "metareplace d1 /dev/dsk/c0t3d0s1 <new device>" Size: 69660 blocks Stripe 0: Device Start Block Dbase State Hot Spare /dev/dsk/c0t3d0s1 0 No Maintenance d21: Submirror of d1 State: Okay Size: 69660 blocks Stripe 0: Device Start Block Dbase State Hot Spare /dev/dsk/c0t2d0s1 0 No Okay d2: Mirror Submirror 0: d12 State: Needs maintenance Submirror 1: d22 State: Okay ... d2: Mirror Submirror 0: d12 State: Needs maintenance Submirror 1: d22 State: Okay ... d12: Submirror of d2 State: Needs maintenance Invoke: "metareplace d2 /dev/dsk/c0t3d0s6 <new device>" Size: 286740 blocks Stripe 0: Device Start Block Dbase State Hot Spare /dev/dsk/c0t3d0s6 0 No Maintenance d22: Submirror of d2 State: Okay Size: 286740 blocks Stripe 0: Device Start Block Dbase State Hot Spare /dev/dsk/c0t2d0s6 0 No Okay |
In this example, the metastat command shows that following submirrors need maintenance:
Submirror d10, device c0t3d0s0
Submirror d11, device c0t3d0s1
Submirror d12, device c0t3d0s6
Halt the system, replace the disk, and use the format command or the fmthard command, to partition the disk as it was before the failure.
Tip –
If the new disk is identical to the existing disk (the intact side of the mirror in this example), use prtvtoc /dev/rdsk/c0t2d0s2 | fmthard -s - /dev/rdsk/c0t3d0s2 to quickly format the new disk (c0t3d0 in this example)
# halt ... Halted ... ok boot ... # format /dev/rdsk/c0t3d0s0 |
Reboot.
Note that you must reboot from the other half of the root (/) mirror. You should have recorded the alternate boot device when you created the mirror.
To delete the failed state database replicas and then add them back, use the metadb command.
# metadb flags first blk block count M p unknown unknown /dev/dsk/c0t3d0s3 M p unknown unknown /dev/dsk/c0t3d0s3 a m p luo 16 1034 /dev/dsk/c0t2d0s3 a p luo 1050 1034 /dev/dsk/c0t2d0s3 a p luo 16 1034 /dev/dsk/c0t1d0s3 a p luo 1050 1034 /dev/dsk/c0t1d0s3 # metadb -d c0t3d0s3 # metadb -c 2 -a c0t3d0s3 # metadb flags first blk block count a m p luo 16 1034 /dev/dsk/c0t2d0s3 a p luo 1050 1034 /dev/dsk/c0t2d0s3 a p luo 16 1034 /dev/dsk/c0t1d0s3 a p luo 1050 1034 /dev/dsk/c0t1d0s3 a u 16 1034 /dev/dsk/c0t3d0s3 a u 1050 1034 /dev/dsk/c0t3d0s3 |
Re-enable the submirrors by using the metareplace command.
# metareplace -e d0 c0t3d0s0 Device /dev/dsk/c0t3d0s0 is enabled # metareplace -e d1 c0t3d0s1 Device /dev/dsk/c0t3d0s1 is enabled # metareplace -e d2 c0t3d0s6 Device /dev/dsk/c0t3d0s6 is enabled |
After some time, the resynchronization will complete. You can now return to booting from the original device.
Recovering From State Database Replica Failures
How to Recover From Insufficient State Database Replicas
If the state database replica quorum is not met, for example, due to a drive failure, the system cannot be rebooted into multiuser mode. This situation could follow a panic (when Solaris Volume Manager discovers that fewer than half the state database replicas are available) or could occur if the system is rebooted with exactly half or fewer functional state database replicas. In Solaris Volume Manager terms, the state database has gone “stale.” This task explains how to recover from this problem.
Boot the system to determine which state database replicas are down.
Determine which state database replicas are unavailable
Use the following format of the metadb command:
If one or more disks are known to be unavailable, delete the state database replicas on those disks. Otherwise, delete enough errored state database replicas (W, M, D, F, or R status flags reported by metadb) to ensure that a majority of the existing state database replicas are not errored.
Delete the state database replica on the bad disk using the metadb -d command.
Tip –
State database replicas with a capitalized status flag are in error, while those with lowercase status flags are functioning normally.
Verify that the replicas have been deleted by using the metadb command.
Reboot.
If necessary, you can replace the disk, format it appropriately, then add any state database replicas needed to the disk. Following the instructions in Creating State Database Replicas.
Once you have a replacement disk, halt the system, replace the failed disk, and once again, reboot the system. Use the format command or the fmthard command to partition the disk as it was configured before the failure.
Example—Recovering From Stale State Database Replicas
In the following example, a disk containing seven replicas has gone bad. This leaves the system with only three good replicas, and the system panics, then cannot reboot into multi-user mode.
panic[cpu0]/thread=70a41e00: md: state database problem 403238a8 md:mddb_commitrec_wrapper+6c (2, 1, 70a66ca0, 40323964, 70a66ca0, 3c) %l0-7: 0000000a 00000000 00000001 70bbcce0 70bbcd04 70995400 00000002 00000000 40323908 md:alloc_entry+c4 (70b00844, 1, 9, 0, 403239e4, ff00) %l0-7: 70b796a4 00000001 00000000 705064cc 70a66ca0 00000002 00000024 00000000 40323968 md:md_setdevname+2d4 (7003b988, 6, 0, 63, 70a71618, 10) %l0-7: 70a71620 00000000 705064cc 70b00844 00000010 00000000 00000000 00000000 403239f8 md:setnm_ioctl+134 (7003b968, 100003, 64, 0, 0, ffbffc00) %l0-7: 7003b988 00000000 70a71618 00000000 00000000 000225f0 00000000 00000000 40323a58 md:md_base_ioctl+9b4 (157ffff, 5605, ffbffa3c, 100003, 40323ba8, ff1b5470) %l0-7: ff3f2208 ff3f2138 ff3f26a0 00000000 00000000 00000064 ff1396e9 00000000 40323ad0 md:md_admin_ioctl+24 (157ffff, 5605, ffbffa3c, 100003, 40323ba8, 0) %l0-7: 00005605 ffbffa3c 00100003 0157ffff 0aa64245 00000000 7efefeff 81010100 40323b48 md:mdioctl+e4 (157ffff, 5605, ffbffa3c, 100003, 7016db60, 40323c7c) %l0-7: 0157ffff 00005605 ffbffa3c 00100003 0003ffff 70995598 70995570 0147c800 40323bb0 genunix:ioctl+1dc (3, 5605, ffbffa3c, fffffff8, ffffffe0, ffbffa65) %l0-7: 0114c57c 70937428 ff3f26a0 00000000 00000001 ff3b10d4 0aa64245 00000000 panic: stopped at edd000d8: ta %icc,%g0 + 125 Type 'go' to resume ok boot -s Resetting ... Sun Ultra 5/10 UPA/PCI (UltraSPARC-IIi 270MHz), No Keyboard OpenBoot 3.11, 128 MB memory installed, Serial #9841776. Ethernet address 8:0:20:96:2c:70, Host ID: 80962c70. Rebooting with command: boot -s Boot device: /pci@1f,0/pci@1,1/ide@3/disk@0,0:a File and args: -s SunOS Release 5.9 Version s81_39 64-bit Copyright 1983-2001 Sun Microsystems, Inc. All rights reserved. configuring IPv4 interfaces: hme0. Hostname: dodo metainit: dodo: stale databases Insufficient metadevice database replicas located. Use metadb to delete databases which are broken. Ignore any "Read-only file system" error messages. Reboot the system when finished to reload the metadevice database. After reboot, repair any broken database replicas which were deleted. Type control-d to proceed with normal startup, (or give root password for system maintenance): root password single-user privilege assigned to /dev/console. Entering System Maintenance Mode Jun 7 08:57:25 su: 'su root' succeeded for root on /dev/console Sun Microsystems Inc. SunOS 5.9 s81_39 May 2002 # metadb -i flags first blk block count a m p lu 16 8192 /dev/dsk/c0t0d0s7 a p l 8208 8192 /dev/dsk/c0t0d0s7 a p l 16400 8192 /dev/dsk/c0t0d0s7 M p 16 unknown /dev/dsk/c1t1d0s0 M p 8208 unknown /dev/dsk/c1t1d0s0 M p 16400 unknown /dev/dsk/c1t1d0s0 M p 24592 unknown /dev/dsk/c1t1d0s0 M p 32784 unknown /dev/dsk/c1t1d0s0 M p 40976 unknown /dev/dsk/c1t1d0s0 M p 49168 unknown /dev/dsk/c1t1d0s0 # metadb -d c1t1d0s0 # metadb flags first blk block count a m p lu 16 8192 /dev/dsk/c0t0d0s7 a p l 8208 8192 /dev/dsk/c0t0d0s7 a p l 16400 8192 /dev/dsk/c0t0d0s7 # |
The system paniced because it could no longer detect state database replicas on slice /dev/dsk/c1t1d0s0, which is part of the failed disk or attached to a failed controller. The first metadb -i command identifies the replicas on this slice as having a problem with the master blocks.
When you delete the stale state database replicas, the root (/) file system is read-only. You can ignore the mddb.cf error messages displayed.
At this point, the system is again functional, although it probably has fewer state database replicas than it should, and any volumes that used part of the failed storage are also either failed, errored, or hot-spared; those issues should be addressed promptly.
Repairing Transactional Volumes
Because a transactional volume is a “layered” volume, consisting of a master device and logging device, and because the logging device can be shared among file systems, repairing a failed transactional volume requires special recovery tasks.
Any device errors or panics must be managed by using the command line utilities.
Panics
If a file system detects any internal inconsistencies while it is in use, it will panic the system. If the file system is configured for logging, it notifies the transactional volume that it needs to be checked at reboot. The transactional volume transitions itself to the “Hard Error” state. All other transactional volumes that share the same log device also go into the “Hard Error” state.
At reboot, fsck checks and repairs the file system and transitions the file system back to the “Okay” state. fsck completes this process for all transactional volumes listed in the /etc/vfstab file for the affected log device.
Transactional Volume Errors
If a device error occurs on either the master device or the log device while the transactional volume is processing logged data, the device transitions from the “Okay” state to the “Hard Error” state. If the device is either in the “Hard Error” or “Error” state, either a device error has occurred, or a panic has occurred.
Any devices sharing the failed log device also go the “Error” state.
Recovering From Soft Partition Problems
The following sections show how to recover configuration information for soft partitions. You should only use these techniques if all of your state database replicas have been lost and you do not have a current or accurate copy of metastat -p output, the md.cf file, or an up-to-date md.tab file.
How to Recover Configuration Data for a Soft Partition
At the beginning of each soft partition extent, a sector is used to mark the beginning of the soft partition extent. These hidden sectors are called extent headers and do not appear to the user of the soft partition. If all Solaris Volume Manager configuration is lost, the disk can be scanned in an attempt to generate the configuration data.
This procedure is a last option to recover lost soft partition configuration information. The metarecover command should only be used when you have lost both your metadb and your md.cf files, and your md.tab is lost or out of date.
Note –
This procedure only works to recover soft partition information, and does not assist in recovering from other lost configurations or for recovering configuration information for other Solaris Volume Manager volumes.
Note –
If your configuration included other Solaris Volume Manager volumes that were built on top of soft partitions, you should recover the soft partitions before attempting to recover the other volumes.
Configuration information about your soft partitions is stored on your devices and in your state database. Since either of these sources could be corrupt, you must tell the metarecover command which source is reliable.
First, use the metarecover command to determine whether the two sources agree. If they do agree, the metarecover command cannot be used to make any changes. If the metarecover command reports an inconsistency, however, you must examine its output carefully to determine whether the disk or the state database is corrupt, then you should use the metarecover command to rebuild the configuration based on the appropriate source.
Read the Configuration Guidelines for Soft Partitions.
Review the soft partition recovery information by using the metarecover command.
# metarecover component-p -d |
In this case, component is the c*t*d*s*name of the raw component. The -d option indicates to scan the physical slice for extent headers of soft partitions.
For more information, see the metarecover(1M) man page.
Example—Recovering Soft Partitions from On-Disk Extent Headers
# metarecover c1t1d0s1 -p -d The following soft partitions were found and will be added to your metadevice configuration. Name Size No. of Extents d10 10240 1 d11 10240 1 d12 10240 1 # metarecover c1t1d0s1 -p -d The following soft partitions were found and will be added to your metadevice configuration. Name Size No. of Extents d10 10240 1 d11 10240 1 d12 10240 1 WARNING: You are about to add one or more soft partition metadevices to your metadevice configuration. If there appears to be an error in the soft partition(s) displayed above, do NOT proceed with this recovery operation. Are you sure you want to do this (yes/no)?yes c1t1d0s1: Soft Partitions recovered from device. bash-2.05# metastat d10: Soft Partition Device: c1t1d0s1 State: Okay Size: 10240 blocks Device Start Block Dbase Reloc c1t1d0s1 0 No Yes Extent Start Block Block count 0 1 10240 d11: Soft Partition Device: c1t1d0s1 State: Okay Size: 10240 blocks Device Start Block Dbase Reloc c1t1d0s1 0 No Yes Extent Start Block Block count 0 10242 10240 d12: Soft Partition Device: c1t1d0s1 State: Okay Size: 10240 blocks Device Start Block Dbase Reloc c1t1d0s1 0 No Yes Extent Start Block Block count 0 20483 10240 |
This example recovers three soft partitions from disk, after the state database replicas were accidentally deleted.
Recovering Configuration From a Different System
You can recover a Solaris Volume Manager configuration, even onto a different system from the original. For example, assume you have a system with an external Multipack of six disks in it, and a Solaris Volume Manager configuration, including at least one state database replica, on some of those disks. If you experience a system failure, you can attach the Multipack to a different system and recover the complete configuration from the local disk set.
Note –
Only recover a Solaris Volume Manager configuration onto a system with no preexisting Solaris Volume Manager configuration. Otherwise, you risk replacing a logical volume on your system with a logical volume that you are recovering, and possibly corrupting your system.
Note –
This process only works to recover volumes from the local disk set.
How to Recover a Configuration
How to Recover a Configuration
Attach the disk or disks that contain the Solaris Volume Manager configuration to a system with no preexisting Solaris Volume Manager configuration.
Do a reconfiguration reboot to ensure that the system recognizes the newly added disks.
Determine the major/minor number for a slice containing a state database replica on the newly added disks.
Use ls -lL, and note the two numbers between the group name and the date. Those are the major/minor numbers for this slice.
# ls -Ll /dev/dsk/c1t9d0s7 brw-r----- 1 root sys 32, 71 Dec 5 10:05 /dev/dsk/c1t9d0s7 |
If necessary, determine the major name corresponding with the major number by looking up the major number in /etc/name_to_major.
# grep " 32" /etc/name_to_major sd 32 |
Update the /kernel/drv/md.conf file with two commands: one command to tell Solaris Volume Manager where to find a valid state database replica on the new disks, and one command to tell it to trust the new replica and ignore any conflicting device ID information on the system.
In the line in this example that begins with mddb_bootlist1, replace the sd in the example with the major name you found in the previous step. Replace 71 in the example with the minor number you identified in Step 3.
#pragma ident "@(#)md.conf 2.1 00/07/07 SMI" # # Copyright (c) 1992-1999 by Sun Microsystems, Inc. # All rights reserved. # name="md" parent="pseudo" nmd=128 md_nsets=4; # #pragma ident "@(#)md.conf 2.1 00/07/07 SMI" # # Copyright (c) 1992-1999 by Sun Microsystems, Inc. # All rights reserved. # name="md" parent="pseudo" nmd=128 md_nsets=4; # Begin MDD database info (do not edit) mddb_bootlist1="sd:71:16:id0"; md_devid_destroy=1;# End MDD database info (do not edit) |
Reboot to force Solaris Volume Manager to reload your configuration.
You will see messages similar to the following displayed to the console.
volume management starting. Dec 5 10:11:53 lexicon metadevadm: Disk movement detected Dec 5 10:11:53 lexicon metadevadm: Updating device names in Solaris Volume Manager The system is ready. |
Verify your configuration by using the metadb and metastat commands.
# metadb flags first blk block count a m p luo 16 8192 /dev/dsk/c1t9d0s7 a luo 16 8192 /dev/dsk/c1t10d0s7 a luo 16 8192 /dev/dsk/c1t11d0s7 a luo 16 8192 /dev/dsk/c1t12d0s7 a luo 16 8192 /dev/dsk/c1t13d0s7 # metastat d12: RAID State: Okay Interlace: 32 blocks Size: 125685 blocks Original device: Size: 128576 blocks Device Start Block Dbase State Reloc Hot Spare c1t11d0s3 330 No Okay Yes c1t12d0s3 330 No Okay Yes c1t13d0s3 330 No Okay Yes d20: Soft Partition Device: d10 State: Okay Size: 8192 blocks Extent Start Block Block count 0 3592 8192 d21: Soft Partition Device: d10 State: Okay Size: 8192 blocks Extent Start Block Block count 0 11785 8192 d22: Soft Partition Device: d10 State: Okay Size: 8192 blocks Extent Start Block Block count 0 19978 8192 d10: Mirror Submirror 0: d0 State: Okay Submirror 1: d1 State: Okay Pass: 1 Read option: roundrobin (default) Write option: parallel (default) Size: 82593 blocks d0: Submirror of d10 State: Okay Size: 118503 blocks Stripe 0: (interlace: 32 blocks) Device Start Block Dbase State Reloc Hot Spare c1t9d0s0 0 No Okay Yes c1t10d0s0 3591 No Okay Yes d1: Submirror of d10 State: Okay Size: 82593 blocks Stripe 0: (interlace: 32 blocks) Device Start Block Dbase State Reloc Hot Spare c1t9d0s1 0 No Okay Yes c1t10d0s1 0 No Okay Yes Device Relocation Information: Device Reloc Device ID c1t9d0 Yes id1,sd@SSEAGATE_ST39103LCSUN9.0GLS3487980000U00907AZ c1t10d0 Yes id1,sd@SSEAGATE_ST39103LCSUN9.0GLS3397070000W0090A8Q c1t11d0 Yes id1,sd@SSEAGATE_ST39103LCSUN9.0GLS3449660000U00904NZ c1t12d0 Yes id1,sd@SSEAGATE_ST39103LCSUN9.0GLS32655400007010H04J c1t13d0 Yes id1,sd@SSEAGATE_ST39103LCSUN9.0GLS3461190000701001T0 # # metadb flags first blk block count a m p luo 16 8192 /dev/dsk/c1t9d0s7 a luo 16 8192 /dev/dsk/c1t10d0s7 a luo 16 8192 /dev/dsk/c1t11d0s7 a luo 16 8192 /dev/dsk/c1t12d0s7 a luo 16 8192 /dev/dsk/c1t13d0s7 # metastat d12: RAID State: Okay Interlace: 32 blocks Size: 125685 blocks Original device: Size: 128576 blocks Device Start Block Dbase State Reloc Hot Spare c1t11d0s3 330 No Okay Yes c1t12d0s3 330 No Okay Yes c1t13d0s3 330 No Okay Yes d20: Soft Partition Device: d10 State: Okay Size: 8192 blocks Extent Start Block Block count 0 3592 8192 d21: Soft Partition Device: d10 State: Okay Size: 8192 blocks Extent Start Block Block count 0 11785 8192 d22: Soft Partition Device: d10 State: Okay Size: 8192 blocks Extent Start Block Block count 0 19978 8192 d10: Mirror Submirror 0: d0 State: Okay Submirror 1: d1 State: Okay Pass: 1 Read option: roundrobin (default) Write option: parallel (default) Size: 82593 blocks d0: Submirror of d10 State: Okay Size: 118503 blocks Stripe 0: (interlace: 32 blocks) Device Start Block Dbase State Reloc Hot Spare c1t9d0s0 0 No Okay Yes c1t10d0s0 3591 No Okay Yes d1: Submirror of d10 State: Okay Size: 82593 blocks Stripe 0: (interlace: 32 blocks) Device Start Block Dbase State Reloc Hot Spare c1t9d0s1 0 No Okay Yes c1t10d0s1 0 No Okay Yes Device Relocation Information: Device Reloc Device ID c1t9d0 Yes id1,sd@SSEAGATE_ST39103LCSUN9.0GLS3487980000U00907AZ1 c1t10d0 Yes id1,sd@SSEAGATE_ST39103LCSUN9.0GLS3397070000W0090A8Q c1t11d0 Yes id1,sd@SSEAGATE_ST39103LCSUN9.0GLS3449660000U00904NZ c1t12d0 Yes id1,sd@SSEAGATE_ST39103LCSUN9.0GLS32655400007010H04J c1t13d0 Yes id1,sd@SSEAGATE_ST39103LCSUN9.0GLS3461190000701001T0 # metastat -p d12 -r c1t11d0s3 c1t12d0s3 c1t13d0s3 -k -i 32b d20 -p d10 -o 3592 -b 8192 d21 -p d10 -o 11785 -b 8192 d22 -p d10 -o 19978 -b 8192 d10 -m d0 d1 1 d0 1 2 c1t9d0s0 c1t10d0s0 -i 32b d1 1 2 c1t9d0s1 c1t10d0s1 -i 32b # |